Product Specification
LC370EUN
Ver. 1.0
The following items are maximum values which, if exceeded, may cause faulty operation or permanent damage
to the LCD module.
2. Absolute Maximum Ratings
Table 1. ABSOLUTE MAXIMUM RATINGS
1. Ambient temperature condition (Ta = 25 ± 2 °C )
2. Temperature and relative humidity range are shown in the figure below.
Wet bulb temperature should be Max 39°C, and no condensation of water.
3. Gravity mura can be guaranteed below 40°C condition.
4. The maximum operating temperatures is based on the test condition that the surface temperature
of display area is less than or equal to 68°C with LCD module alone in a temperature controlled chamber.
Thermal management should be considered in final product design to prevent the surface temperature of
display area from being over 68℃. The range of operating temperature may be degraded in case of
improper thermal management in final product design.
Parameter Symbol
Value
Unit Note
Min Max
Power Input Voltage
LCD Circuit VLCD -0.3 +14.0 VDC
1
Driver VBL -0.3 + 27.0 VDC
Driver Control Voltage
ON/OFF VOFF / VON -0.3 +5.5 VDC
Brightness EXT VBR-B -0.3 +4.0 VDC
T-Con Option Selection Voltage VLOGIC -0.3 +4.0 VDC
Operating Temperature TOP 0 +50 °C
2,3
Storage Temperature TST -20 +60 °C
Panel Front Temperature TSUR - +68 °C 4
Operating Ambient Humidity HOP 10 90 %RH
2,3
Storage Humidity HST 10 90 %RH
Notes
90%
10 20 30 40 50 60 70 800-20
0
10
20
30
40
50
Dry Bulb Temperature [°C]
Wet Bulb
Temperature [°C]
Storage
Operation
Humidity [(%)RH]
10%
40%
60%
60
4/36