Encore SP201-SA Bedienungsanleitung Seite 13

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 14
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 12
SP201-SA™ Installation Guide 13
E.6 Channel Configuration for NI2 ISDN
In the two-port SP201-SA, perform the following procedure once for trunk 2. In the four-port SP201-SA,
perform the procedure once each for trunks 3 and 4.
Note: If you are performing this procedure on a two-port SP201-SA, read trunk 3 as trunk 2.
What the terminal displays What you type What you are configuring
user> config dchans
ISDN signaling channel
The following is the present Trunk
configuration.
If a change to the Timeslot or
Interface Type is desired
Enter the Trunk number you wish to
modify or exit:
Trunk Signaling Timeslot Trunk Link Interface Protocol
Type Type State Type
-------------------------------------------------------------------------
3 D 24 T1 Inactive Network NI2 ISDN
4 D 24 T1 Inactive Network NI2 ISDN
ISDN Trunk Number
Enter value(3 - 4) or "exit" :
p
where p is the port
number (3 or 4) ISDN trunk p
Select interface type - user(0) or
network(1) : <current=1> 1 (or 0)
SP201-SA as the Network role
(or as the User role) in this
ISDN connection
ISDN Interface number 1 assigned to
Trunk
p
,
with a D Channel on timeslot 24.
Change ISDN Signaling Channel
Enter value(1 - 31; current="24") or
"exit" : 24
Signaling timeslot
(The following message appears only if you change
the channel number used as the signaling timeslot.)
Changes applied
The card must be reset for the
changes to operate properly
Do you wish to reset now (y/n)?
n
Delay in implementation of
changes until performing a
warmstart (described in
Section F, SP201-SA
Warmstart)
not resetting...
user>
(ISDN signaling has been
configured on this trunk.)
Seitenansicht 12
1 2 ... 8 9 10 11 12 13 14

Kommentare zu diesen Handbüchern

Keine Kommentare