6 SP201-SA™ Installation Guide
D Trunk Configuration
Perform the following procedure once for each trunk on the SP201-SA.
What the terminal displays What you type What you are configuring
user>
config framer
p
where p is the port
number (1, 2, 3,
or 4) Trunk on port p
WARNING: Configuring framers will
cause LOSS of calls!!!!!!!!
Do you wish to proceed anyway (Y/N) : y
For a T1 line:
LIM type: 2 T1 100 Ohm/2 E1 120 Ohm
1 D4 SF
2 D4 ESF
enter T1 frame type (currently
D4 SF):
For T1 lines: 1
or your T1 frame
type)
For an E1 line:
LIM type: 2 E1 120 Ohm/2 E1 120 Ohm
1 G704 CRC
2 G704 noCRC
3 G704 MF CRC
4 G704 MF noCRC
enter E1 frame type (currently
G704 MF no CRC):
For E1 lines: 3
(or your E1 frame
type) Frame type for trunk
For T1 lines:
line coding type choices are:
1 AMI
2 B8ZS
enter line coding type (currently
B8ZS) :
For T1 lines: 2
(or your T1 line
coding)
For E1 lines:
line coding type choices are:
1 AMI
2 HDB3
enter line coding type (currently
HDB3) :
For E1 lines: 2
(or your E1 line
coding)
Line coding for trunk
For T1 lines:
line length choices are:
1 0 to 115 feet
2 82 to 213 feet
3 180 to 312 feet
4 279 to 410 feet
5 377 to 509 feet
6 476 to 607 feet
7 574 to 689 feet
enter line length (currently
0-115 feet):
1 (or your T1 cable
length)
T1 cable length
user >
(The trunk has been
configured.)