System Configuration 2-11
SP201-SA™ Customization and Maintenance Guide
Note: In all commands, make sure you type the port number or trunk
number that corresponds to the port you are configuring, regardless of the
port or trunk number shown in the instructions.
For details of SP201-SA port numbering, see the Note in Section 1.3,
Connecting the SP201-SA to the Telephony Network.
Perform the following steps to configure the system-level parameters:
1 Use the config time command to set the SignalPath’s time. See
Section 2.3.1, The config time Command.
2 Use the config lim command to configure the impedances on the port
interfaces. See Section 2.3.2, The config lim Command.
Table 2-6. System-Level Configuration Commands
Command Name Description
config time Configures the time for the SP201-SA. See
Section 2.3.1, The config time Command.
config lim Configures the port interfaces on the
SP201-SA. See Section 2.3.2, The config lim
Command.
Note: The config lim command affects the
parameters that other commands present. You
must perform the config lim command before
performing any other commands.
config clocks Specifies the primary and secondary clock
sources for the system. See Section 2.3.3, The
config clocks Command.
config framers Configures hardware parameters for
individual trunks. See Section 2.3.4, The
config framer Command.
config alarms Enables or disables trunk alarm reporting.
See Section 2.3.5, The config alarms Command.
config almrelay Relays alarm conditions to other trunks. See
Section 2.3.6, The config almrelay Command.